Parameter list | C01100
988
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01100
C01101
C01120
Parameter | Name:
C01100 | Function L_Counter 1-3
Data type: UNSIGNED_8
Index: 23475
d
= 5BB3
h
Selection of reset function
Selection list
0 Normal counting
1 Auto reset
2 Manual reset
Subcodes
Lenze setting
Info
C01100/1
0: Normal counting
: Function
C01100/2
0: Normal counting
: Function
C01100/3
0: Normal counting
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01101 | Comparison L_Counter 1-3
Data type: UNSIGNED_8
Index: 23474
d
= 5BB2
h
Selection of comparison operation
Selection list
0 Greater than or equal to
1 Less than or equal to
2 equal to
Subcodes
Lenze setting
Info
C01101/1
0: Greater than or equal to
: Comparison
C01101/2
0: Greater than or equal to
: Comparison
C01101/3
0: Greater than or equal to
: Comparison
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01120 | Sync signal source
Data type: UNSIGNED_8
Index: 23455
d
= 5B9F
h
Selection of the signal source for device synchronisation
• The drive can only be synchronised by one source.
Selection list
(Lenze setting printed in bold)
Info
0 Off
Synchronisation off
1 CAN on board
Synchronisation via CAN bus
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1