C00448 | digout decoupling value, C00449 | freqinxx_dnout_p, C00449/1 – Lenze 8400 User Manual
Page 830: C00448, Specifyin, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C00448
830
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00448
C00449
C00455
Parameter | Name:
C00448 | DigOut decoupling value
Data type: UNSIGNED_16
Index: 24127
d
= 5E3F
h
From version 02.00.00
Definition of the value the digital output terminals are to have in the decoupled state.
• Bit set = HIGH level
Configuring exception handling of the output terminals
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Bit 0 Reserved
Bit 1 DigOut1_ON
Bit 2 DigOut2_ON
Bit 3 Reserved
Bit 4 Reserved
Bit 5 BrakeRelease_ON
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00449 | FreqInxx_dnOut_p
Data type: INTEGER_32
Index: 24126
d
= 5E3E
h
From version 06.00.00
Output of the encoder position of the DI1/DI2 frequency input
Display range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Info
C00449/1
FreqIn12_dnOut_p
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00455 | FB_call table
Data type: UNSIGNED_16
Index: 24120
d
= 5E38
h
This code is for device-internal use only and must not be written to by the user!