C00148 | ls_driveinterface: error message config, C00148, The short16 – Lenze 8400 User Manual
Page 773: 1") in, Is activated in, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
773
16
Parameter reference
16.2
Parameter list | C00148
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00148
Parameter | Name:
C00148 | LS_DriveInterface: Error message config.
Data type: UNSIGNED_16
Index: 24427
d
= 5F6B
h
From version 02.00.00
Selection of the device statuses for which the bCollectedFail group error output of SB
is to be set
to TRUE.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0030 (decimal: 48)
Value is bit-coded: ( = bit set)
Info
Bit 0 SafeTorqueOff
Bit 1 ReadyToSwitchOn
Bit 2 SwitchedOn
Bit 3 TroubleQSP
From version 06.00.00
Bit 4 Trouble
Bit 5 Fault
Bit 6 Warning
Bit 7 ImpIsActive
Bit 8 CInhIsActive
Bit 9 Fail CAN_Management
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Lock bFail at TroubleQSP
From version 12.00.00
If this bit is set, the bFail output of the
SB
is also set in the "TroubleQSP"
status.
• Advantage: Even in the "TroubleQSP" status, an error
occurred before can still be recognised.
Bit 15 Use 16BitFailNo.
From version 06.00.00
If this bit is set, the short 16-bit error number
(wStateDetermFailNoShort) is also provided at the
wStateDetermFailNoLow output of the
SB
.
• In this case, the wStateDetermFailNoHigh output is
"0".
• Advantage: The bus transfer of the error numbers is
possible via a data word without changing the
interconnection of the technology application.
Read access Write access CINH PLC STOP No transfer COM MOT