18 function library – Lenze 8400 User Manual
Page 1181

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1181
18
Function library
18.1
Function blocks | L_CalcDiameter_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0.001
Rev.
2.000 Diameter recalculation 0
• Number of revolutions after
which a diameter calculation is
executed.
• Setting is effective when bCalcRef
= FALSE.
• Initialisation: 1.000
0.001
Rev.
2.000 Diameter recalculation 1
• Number of revolutions after
which a diameter calculation is
executed.
• Setting is effective when bCalcRef
= TRUE.
• Initialisation: 0.100
0.010
s
3.000 Filter time constant for calculated
diameter values
• Initialisation: 1.000 s
0.00
%
100.00 Permissible diameter change in
opposite direction (web break
monitoring)
• Only relevant when bUnidirect =
TRUE.
• Referring to the maximum
diameter (wMaxDiameter).
• Initialisation: 10.00 %
0.000
mm
10000.000 Current diameter
• Read only
Invert. gearbox nMotorSpeedAct_v
0 not inverted
1 inverted
2 Automatically from MCK
Parameter
Possible settings
Info