beautypg.com

174 l_transient_8, 174 l_transient_8 8, L_transient_8 – Lenze 8400 User Manual

Page 1428: 18 function library

background image

18

Function library

18.1

Function blocks | L_Transient_8

1428

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.174

L_Transient_8

This FB serves to evaluate digital signal edges and convert them into timed, retriggerable pulses.

Rising signal edges, falling signal edges or both signal edges can be evaluated.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

bIn

BOOL

Input for edge evaluation

• The function depends on the selection of edge evaluation in

C01140/4

.

Identifier

Data type

Value/meaning

bOut

BOOL

Output (retriggerable)

Parameter

Possible settings

Info

C01140/4

Function

• Selection of edge evaluation

0 High edge

Lenze setting

1 Low edge
2 High and low edge

C01141/4

0.001

s

60.000 Pulse duration

• Lenze setting: 0.001 s

For a detailed functional description see

L_Transient_1

.

E2XW

E,Q

W

&

&

/B

B

7UDQVLHQW