1 function 0: evaluate rising signal edges, 2 function 1: evaluate falling signal edges, 1 function 0: evaluate rising signal edges 0 – Lenze 8400 User Manual
Page 1420: 2 function 1: evaluate falling signal edges 0, 18 function library

18
Function library
18.1
Function blocks | L_Transient_1
1420
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.167.1 Function 0: Evaluate rising signal edges
[18-70] Switching performance for function selection "0: High edge"
Functional sequence
1. A FALSE-TRUE edge at the bIn input sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless
another FALSE/TRUE edge has been set at the bIn input.
• If an additional FALSE-TRUE edge occurs at the bIn input, the pulse duration starts again from
the beginning, i.e. the bOut output can be retriggered.
18.1.167.2 Function 1: Evaluate falling signal edges
[18-71] Switching performance for function selection "1: Low edge"
Functional sequence
1. A TRUE-FALSE edge at the bIn inputs sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless
another TRUE/FALSE edge has been set at the bIn input.
• If an additional TRUE-FALSE edge occurs at the bIn input, the pulse duration starts again from
the beginning, i.e. the bOut output can be retriggered.
Pulse duration
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t
Pulse duration
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t