beautypg.com

153 l_signalswitch_1, 153 l_signalswitch_1 9, L_signalswitch_1 – Lenze 8400 User Manual

Page 1399: 18 function library

background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1399

18

Function library

18.1

Function blocks | L_SignalSwitch_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.153

L_SignalSwitch_1

This FB switches between two input signals of the "WORD" data type. The switch-over is controlled

by means of a boolean input signal.

Inputs

Outputs

Identifier

Data type

Information/possible settings

wIn1

WORD

Input signal 1

wIn2

WORD

Input signal 2

bSet

BOOL

Selection of the input signal for the output at wOut

FALSE wIn1

TRUE wIn2

Identifier

Data type

Value/meaning

wOut

WORD

Output signal

/B6LJQDO6ZLWFKB

Z,Q

Z2XW

Z,Q