18 function library – Lenze 8400 User Manual
Page 1266

18
Function library
18.1
Function blocks | L_DFSET_1
1266
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Setting is bit coded:
Setting
• Lenze setting: 0x02
Bit 0 Setpoint angle without gearbox
factor
0 = Evaluation of the setpoint angle
with gearbox factor.
1 = Evaluation of the setpoint angle
without gearbox factor.
Bit 1 Angle correction with polynomial
0 = Angle correction without
downstream polynomial.
1 = Angle correction with
downstream polynomial.
Bit 2 Reserved
...
Bit 7
0
16384 Divisor for actual value zero pulse
• Number of signals to be received
at least until synchronisation gets
active.
• Initialisation: 0
0
16384 Divisor for setpoint zero pulse
• Number of signals to be received
at least until synchronisation gets
active.
• Initialisation: 0
Synchronisation mode - mark
correction
0 Synchronisation inactive
Lenze setting
1 Permanent synchronisation without
enable via the bZeroPulse input
• Correction is executed over the
shortest possible path.
The synchronisation only takes place
after 2 setpoint pulses have been
received at the bSetTPReceived input.
(required pulse order: set-actual-set)
2 Permanent synchronisation only
with enable via the bZeroPulse input
• When bZeroPulse is set to TRUE, a
permanent zero pulse/touch
probe synchronisation is
executed.
• Correction is executed over the
shortest possible path.
10 One-time synchronisation
• An angular difference is
compensated over the shortest
possible path.
11 One-time synchronisation
• An angle difference is
compensated in CW direction.
12 One-time synchronisation
• An angular difference is
compensated in CCW direction.
13 One-time synchronisation
• An angular difference is
compensated over the shortest
possible path.
Synchronisation takes place after the
first setpoint pulse has been received
at the bSetTPReceived input and/or
actual value pulse at the
bActTPReceived input.
(Required clock sequence: Set/actual
or actual/set)
Parameter
Possible settings
Info