92 l_gainoffsetphip_1, 92 l_gainoffsetphip_1 8, L_gainoffsetphip_1 – Lenze 8400 User Manual
Page 1298: 18 function library

18
Function library
18.1
Function blocks | L_GainOffsetPhiP_1
1298
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.92
L_GainOffsetPhiP_1
This FB can amplify an angle signal and add an offset to it afterwards.
• The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow. Division is not remainder considered.
• Gain and offset are selected via parameters.
• The value provided at the dnOut_p output is internally limited to ±2
31
-1.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2
31
-1 (±2147483647)
Parameter
Possible settings
Info
-2147483647
Incr.
2147483647 Offset
• Lenze setting: 0 incr.
-2147483647
2147483647 Gain factor
• Lenze setting: 65536
/B*DLQ2IIVHW3KL3B
GQ,QBS
GQ2XWBS
2IIVHW
*DLQ
&
&
r
dnOut_p
dnIn_p Gain factor
⋅
(
) Offset
+
=