Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
63
3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.8
Commissioning of the "Table positioning" technology application
[3-2]
Block diagram for wiring the commissioning example for the "Table positioning" application
Note!
Take all the necessary safety precautions before you carry out the following
commissioning steps and switch the device on!
Safety instructions with regard to commissioning
System constellation
X41/DI1
Position encoder connection, track A
X41/DI2
Position encoder connection, track B
X42/DI3
Hardware limit switch connection in positive direction
X42/DI4
Hardware limit switch connection in negative direction
X43/DI5
Profile selection and change of operating mode at the same time:
LOW level: Selection of profile number 1 and "Homing" operating mode
HIGH level: Selection of profile number 3 and "Positioning" operating mode
X43/DI6
Start of profile generation
X70
Diagnostic interface for connecting the USB diagnostic adapter
8400 protec
X61
X6
DIAG
AR A1U GA
X50
24O DI1 DI2 GIO
X41
24O DI3 DI4 GIO
X42
24O DI5 DI6 GIO
X43
U
V W
X70
M
3~
0-Position
20
30
10
-10
-20
-30
40
i
A
B
DI6: PosExecute
DI5: PosProfile