9diagnostics & error management – Lenze 8400 User Manual
Page 582

9
Diagnostics & error management
9.10
Error messages of the operating system
582
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error ID
16-bit value (0 ... 65535) for error identification within the error subject area.
Example for bit coding of the error number
displays the internal error number "142278671".
• This decimal value corresponds to the following bit sequence:
• Thus, error number "142278671" means:
A DC bus undervoltage has been detected in the "Motor management / encoder" subject area.
The error response is a "Fault" which must be unlocked separately after the error has been
eliminated.
Assignment
Information
Meaning in the example
Reserved
-
Error type
2: Trouble
Error subject area
123: Motor management / encoder
Error ID
Bit
16
25
26
31
0
15
29
30
2
1
0
3
Bit
16
25
26
31
0
15
29
30
0 0 0 0 1 0 0 0 0 1 1 1 1 0 1 1 0 0 0 0
0 0 0 0 0 0 1 1 1 1
0
0
0 0
0 0 1 0
0 0 0 1 1 1 1 0 1 1
0 0 0 0
0 0 0 0 0 0 1 1 1 1
0
0