C02652
C02810
Parameter | Name:
C02652 | Settings of measuring system
Data type: UNSIGNED_16
Index: 21923
d
= 55A3
h
From version 12.00.00
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Info
Bit 0 Actual MCTRL position received at
mains switch-off
Bit 1 Delete reference when machine data
is changed
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02810 | TP: Edge selection
Data type: UNSIGNED_8
Index: 21765
d
= 5505
h
From version 06.00.00
Selection list
0 Off
1 Rising
2 Falling
3 Rising and falling
Subcodes
Lenze setting
Info
C02810/1
0: Off
Reserved
C02810/2
0: Off
Reserved
C02810/3
0: Off
Reserved
C02810/4
0: Off
TPDigIn4: Edge selection
C02810/5
0: Off
TPDigIn5: Edge selection
C02810/6
0: Off
TPDigIn6: Edge selection
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1