C00161 | ls_seterror_x: error number, C00163 | logbook - binary elements, C00163/1 – Lenze 8400 User Manual
Page 778: C00163/2, C161/1, C161/2, C161/3, C161/4, C161/5, C161/6

16
Parameter reference
16.2
Parameter list | C00161
778
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00161
C00163
Parameter | Name:
C00161 | LS_SetError_x: Error number
Data type: UNSIGNED_16
Index: 24414
d
= 5F5E
h
Setting of the error number for user error messages
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00161/1
1
: Error no.1
C00161/2
2
: Error no.2
C00161/3
3
: Error no.3
C00161/4
4
: Error no.4
C00161/5
1
: Error no.1
C00161/6
2
: Error no.2
C00161/7
3
: Error no.3
C00161/8
4
: Error no.4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00163 | Logbook - binary elements
Data type: UNSIGNED_16
Index: 24412
d
= 5F5C
h
Selection of two binary signals to be logged in the logbook
Selection list
Info
0 No signal
1 DI1: Input signal
2 DI2: Input signal
3 DI3: Input signal
4 DI4: Input signal
5 Controller inhibit signal
6 Digital counter: Comparison bit
7 CAN1 input bit 0
8 CAN1 input bit 1
9 CAN1 input bit 2
10 CAN1 input bit 3
11 CAN1 input bit 4
12 CAN1 input bit 5
13 CAN1 input bit 6
14 CAN1 input bit 7
15 CAN1 input bit 8
16 CAN1 input bit 9
17 CAN1 input bit 10
18 CAN1 input bit 11
19 CAN1 input bit 12
20 CAN1 input bit 13
21 CAN1 input bit 14
22 CAN1 input bit 15
23 CAN2 input bit 0