C00227 | l_pctrl_1: acceleration time, C00228 | l_pctrl_1: deceleration time, C00231 | l_pctrl_1: operating range – Lenze 8400 User Manual
Page 794: C00233 | l_pctrl_1: root function, C00227, C00228, C00233, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C00227
794
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00227
C00228
C00231
C00233
Parameter | Name:
C00227 | L_PCTRL_1: Acceleration time
Data type: UNSIGNED_32
Index: 24348
d
= 5F1C
h
FB: Acceleration time for the output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 0.010 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00228 | L_PCTRL_1: Deceleration time
Data type: UNSIGNED_32
Index: 24347
d
= 5F1B
h
FB: Deceleration time for the output value of the PID process controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 0.010 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00231 | L_PCTRL_1: Operating range
Data type: INTEGER_16
Index: 24344
d
= 5F18
h
FB: Operating range for the PID process controller
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00231/1
199.99 %
: Pos. maximum
C00231/2
0.00 %
: Pos. minimum
C00231/3
0.00 %
: Neg. minimum
C00231/4
199.99 %
: Neg. maximum
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00233 | L_PCTRL_1: Root function
Data type: UNSIGNED_8
Index: 24342
d
= 5F16
h
FB: Use of the root function at the actual value input
Selection list
(Lenze setting printed in bold)
Info
0 Off
Root function inactive
• The actual value nAct_a remains unchanged for
further processing
1 On
Root function active
• The root is extracted of the actual value nAct_a for
further processing
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1