C01022 | l_odometer_1: input selection, C01023 | l_odometer_1: edge selection, C01025 | l_curve_2: selected curve type – Lenze 8400 User Manual
Page 966: C01026 | l_curve_2: input limitation, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C01022
966
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01022
C01023
C01025
C01026
Parameter | Name:
C01022 | L_Odometer_1: Input selection
Data type: UNSIGNED_8
Index: 23553
d
= 5C01
h
FB
: Selection of position or speed input
Selection list
(Lenze setting printed in bold)
0 Pos input
1 V input
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01023 | L_Odometer_1: Edge selection
Data type: UNSIGNED_8
Index: 23552
d
= 5C00
h
FB
: No. of the edge triggering the measurement
Selection list
(Lenze setting printed in bold)
0 High edge
1 Low edge
2 High and low edge
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01025 | L_Curve_2: Selected curve type
Data type: UNSIGNED_8
Index: 23550
d
= 5BFE
h
From version 12.00.00
FB
: Selected curve type
Selection list
0 Out = 0
1 Out = In
2 Out = f(In)
3 Out = f(table)
Subcodes
Lenze setting
Info
C01025/1
1: Out = In
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01026 | L_Curve_2: Input limitation
Data type: INTEGER_16
Index: 23549
d
= 5BFD
h
From version 12.00.00
FB
: Upper and lower limit for input value
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C01026/1
199.99 %
: Max. input
C01026/2
-199.99 %
: Min. input
Read access Write access CINH PLC STOP No transfer COM MOT