2 configuring control inputs, 3 functional settings, Configuring control inputs – Lenze 8400 User Manual
Page 723: Functional settings, 15 parameter change-over

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
723
15
Parameter change-over
15.1
Configuring parameter change-over via the »Engineer« parameterisation dialog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
15.1.2
Configuring control inputs
The three control inputs for parameter change-over can be configured via the following parameters:
Truth table for the selection of the value set to be used:
15.1.3
Functional settings
Parameter
Lenze setting
Info
Activate writing
(
0: Not connected
Selection of the signal source that activates writing
to the parameter list (for
= "0: by
Execute").
Selection value set - 1
(
0: Not connected
Selection of the two signal sources for the binary-
coded selection of the value set 1 ... 4 to be used (see
following truth table).
Selection value set - 2
(
0: Not connected
Selection value set - 1
Selection value set - 2
Value set used
FALSE
FALSE
Value set 1
TRUE
FALSE
Value set 2
FALSE
TRUE
Value set 3
TRUE
TRUE
Value set 4