beautypg.com

20 ls_parfree_a, 20 ls_parfree_a 8, Ls_parfree_a – Lenze 8400 User Manual

Page 1448: 18 function library

background image

18

Function library

18.2

System blocks | LS_ParFree_a

1448

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.2.20

LS_ParFree_a

This system block outputs 16 parameterisable analog signals.

Outputs

Parameter

Identifier

Data type

Value/meaning

nPar1_a ... nPar16_a

INT

From version 12.00.00:

nC472_1_a ... nC472_16_a

Output of the analog signals parameterised in

C00472/1...16

Note:

From version 12.00.00

the outputs are named according to the respective

setting parameter for an easier allocation.

Parameter

Possible settings

Info

C00472/1...16

-199.99

%

+199.99 Selection of analog signals to be

output

/6B3DU)UHHBD

&

&

&

&

&

Q3DUBD

Q3DUBD

Q3DUBD

Q3DUBD

Q3DUBD