C01902 | diagnostics x70: max. baud rate, C01770, 16 parameter reference – Lenze 8400 User Manual
Page 1020

16
Parameter reference
16.2
Parameter list | C01763
1020
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01763
C01764
C01765
C01770
C01902
Parameter | Name:
C01763 | Service code -clamp threshold
Data type: INTEGER_16
Index: 22812
d
= 591C
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01764 | Service par. clamp time
Data type: UNSIGNED_8
Index: 22811
d
= 591B
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01765 | Service code - difference threshold UG
Data type: UNSIGNED_16
Index: 22810
d
= 591A
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01770 | Filter time - earth-fault detect. is running
Data type: UNSIGNED_8
Index: 22805
d
= 5915
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
250 2 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01902 | Diagnostics X70: Max. baud rate
Data type: UNSIGNED_16
Index: 22673
d
= 5891
h
Maximally permissible baud rate in the standard device after determination of the baud rate at the diagnostic
interface X70
Selection list
(Lenze setting printed in bold)
192 19.200 Bd
384 38.400 Bd
576 57.600 Bd
750 75.000 Bd
1152 115.200 Bd
1500 150.000 Bd
2500 250.000 Bd
3750 375.000 Bd
7500 750.000 Bd
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1