C00490 | position encoder selection, C00495 | speed sensor selection, C00496 | encoder evaluation method digin12 – Lenze 8400 User Manual
Page 842: C00490, Select "encoder, C00495, C00496, In12" in, C00495/1, Selected in

16
Parameter reference
16.2
Parameter list | C00490
842
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00490
C00495
C00496
Parameter | Name:
C00490 | Position encoder selection
Data type: UNSIGNED_8
Index: 24085
d
= 5E15
h
Selection of the feedback system for the generation of the actual position on the load
Selection list
(Lenze setting printed in bold)
Info
0 No sensor: nSpeedSetValue_a
No encoder available on the load.
The position signal dnMotorPosAct_p is derived from the
speed setpoint nSpeedSetValue_a.
1 Sensor signal FreqIn12
Position encoder signal is fed via digital inputs DI1 and
DI2
2 Sensor signal FreqIn56
Position encoder signal is fed via digital inputs DI5 and
DI6
10 No sensor: C495 or
nMotorSpeedAct_v
From version 12.00.00
The position signal dnMotorPosAct_p is either calculated
from the set speed feedback (for
> 0) or from the
speed signal nMotorSpeedAct_v (for
= 0).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00495 | Speed sensor selection
Data type: UNSIGNED_8
Index: 24080
d
= 5E10
h
Selection of the feedback system for the actual speed for motor control and display
Selection list
(Lenze setting printed in bold)
Info
0 No sensor
No sensor available for the actual speed detection
1 Sensor signal FreqIn12
Speed sensor signal is fed via the digital DI1 and DI2
inputs
2 Sensor signal FreqIn56
Speed sensor signal is fed via the digital DI5 and DI6
inputs
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00496 | Encoder evaluation method DigIn12
Data type: UNSIGNED_8
Index: 24079
d
= 5E0F
h
Selection list
(Lenze setting printed in bold)
Info
0 High-resolution encoders
High-precision procedure for high-resolution encoders
(>=512 increments)
1 Low-resolution encoder (StateLine)
High-precision procedure for low-resolution encoders
(<=128 increments)
2 Comb. encoder procedure
Combination of the first two procedures as a function of
the speed (recommended procedure)
3 Edge-counting procedure
Simple edge counting procedure with adjustable
scanning time (
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1