Oc5: ixt overload, Oc7: motor overcurrent, Ot1: maximum torque reached – Lenze 8400 User Manual
Page 591: Xx.0119.00050, Xx.0123.00007, Xx.0119.00016, Xx.0123.00001, 9diagnostics & error management

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
591
9
Diagnostics & error management
9.10
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
oH5: Brake resistor temperature (X20) tripped [xx.0119.00016]
oC5: Ixt overload [xx.0119.00050]
ot1: Maximum torque reached [xx.0123.00001]
oC7: Motor overcurrent [xx.0123.00007]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The brake resistor temperature monitoring at plug X20
has been tripped.
Possible causes:
• The external brake resistor is overheated so that the
thermal contact integrated in the brake resistor has
been switched.
• An open circuit or a loose contact at the connections
mentioned above has occurred.
• Check brake resistor temperature monitoring.
• Provide for sufficient cooling of the external brake
resistor.
• Check terminals for open circuit or loose contact.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The Ixt overload check has tripped.
Possible causes:
• Wrong dimensioning of the device with regard to its
motor load.
• Load cycles are not complied with.
• Check and, if required, correct dimensioning of the
device and the motor load with regard to technical
data.
• Reduce motor load cycles (observe load cycles
according to documentation).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The device indicates that the maximally possible torque
at the motor shaft has been reached.
•
displays the current torque.
Reduce motor load.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The maximum current monitoring has tripped.
Check and, if required, correct dimensioning of the load
with regard to the installed device power.