_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01070
C01071
C01072
C01073
Parameter | Name:
C01070 | L_DFSET_1: Angular trimming
Data type: INTEGER_32
Index: 23505
d
= 5BD1
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
-134217728
Incr.
134217728
Subcodes
Lenze setting
Info
C01070/1
0 incr.
: Speed-dependent angle adjustment
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01071 | L_DFSET_1: Following error limit
Data type: UNSIGNED_32
Index: 23504
d
= 5BD0
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
10
Incr.
2147483647
Subcodes
Lenze setting
Info
C01071/1
32768 incr.
: Following error limit
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01072 | L_DFSET_1: Multiplier - angular trimming
Data type: INTEGER_16
Index: 23503
d
= 5BCF
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
-20000
20000
Subcodes
Lenze setting
Info
C01072/1
1
: Multiplier - angular trimming
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01073 | L_DFSET_1: Adjustment
Data type: UNSIGNED_8
Index: 23502
d
= 5BCE
h
From version 12.00.00
Setting range
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 Setpoint angle without gearbox
factor
Bit 1 Angle correction with polynomial
Subcodes
Lenze setting
Info
C01073/1
0x02
: Adjustment