C02580 | holding brake: operating mode, C02580, 16 parameter reference – Lenze 8400 User Manual
Page 1052

16
Parameter reference
16.2
Parameter list | C02314
1052
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02314
C02580
Parameter | Name:
C02314 | Sensibility - Setpoint feedforward control
Data type: UNSIGNED_8
Index: 22261
d
= 56F5
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Selection list
0 Inactive
1 15 bits
2 14 bits
3 13 bits
4 12 bits
5 11 Bit
6 10 Bit
7 9 Bit
Subcodes
Lenze setting
Info
C02314/1
0: Inactive
Sensibility - Setpoint feedforward control
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02580 | Holding brake: Operating mode
Data type: UNSIGNED_8
Index: 21995
d
= 55EB
h
Selection of the operating mode for holding brake control
Selection list
(Lenze setting printed in bold)
Info
0 Brake control off
No holding brake is used. Internal control is switched off.
11 Manually controlled
The holding brake is released and closed via a control bit
in the MCK control word.
12 Autom. controlled
The holding brake is automatically released and closed
via speed setpoint comparisons.
13 Semi-automat. controlled
From version 06.00.00
The holding brake is released and closed via a control bit
in the MCK control word.
• In contrast to the manual operation (mode 11)
• the feedforward control is active in this mode,
preventing a sagging e.g. in case of a hoist.
• the brake in this mode also closes when the
controller is inhibited in order to prevent the axis in
a hoist from falling.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1