16
Parameter reference
16.2
Parameter list | C00964
956
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00964
C00965
C00966
Parameter | Name:
C00964 | L_Curve_1: Table Y-values
Data type: INTEGER_16
Index: 23611
d
= 5C3B
h
FB
: Y-value for characteristic function
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C00964/1
0
Y values 1 ... 32 for characteristic function
C00964/...
C00964/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00965 | Max. motor speed
Data type: UNSIGNED_16
Index: 23610
d
= 5C3A
h
From version 12.00.00
When the drive reaches the motor speed set here:
• The "Fault" error response takes place, i.e. the motor is shut down immediately.
" is entered into the logbook.
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
60000 60000 rpm
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00966 | VFC: Time const. slip comp.
Data type: UNSIGNED_16
Index: 23609
d
= 5C39
h
Filter time constant of the slip compensation for V/f characteristic control (
)
• The time constant of slip compensation serves to specify the dynamics of slip compensation for V/f characteristic
control without feedback.
• The lower the selected time constant, the higher the dynamic performance of the slip compensation.
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
6000 100 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1