C01077 | l_dfrfg_1: max. speed-up, C01078 | l_dfrfg_1: following error, C01079 | l_dfrfg_1: synchronisation window – Lenze 8400 User Manual
Page 980: C01080 | l_dfrfg_1: offset, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C01077
980
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01077
C01078
C01079
C01080
Parameter | Name:
C01077 | L_DFRFG_1: Max. speed-up
Data type: INTEGER_16
Index: 23498
d
= 5BCA
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
1
rpm
15000
Subcodes
Lenze setting
Info
C01077/1
3000 rpm
: Max. speed-up
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01078 | L_DFRFG_1: Following error
Data type: UNSIGNED_32
Index: 23497
d
= 5BC9
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
10
Incr.
2000000000
Subcodes
Lenze setting
Info
C01078/1
2000000000 incr.
: Following error limit
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01079 | L_DFRFG_1: Synchronisation window
Data type: UNSIGNED_16
Index: 23496
d
= 5BC8
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
Incr.
65535
Subcodes
Lenze setting
Info
C01079/1
100 incr.
: Synchronisation window (position)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01080 | L_DFRFG_1: Offset
Data type: INTEGER_32
Index: 23495
d
= 5BC7
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Lenze setting
Info
C01080/1
0 incr.
: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1