C01235 | mck: manual jog waiting times, C01236 | mck: speed follower, C01237 | mck: acceleration follower – Lenze 8400 User Manual
Page 1004: C01235/1, Waiting time 2nd speed (lenze setting, C01236/1, C01237/1, C01237/2, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C01235
1004
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01235
C01236
C01237
Parameter | Name:
C01235 | MCK: Manual jog waiting times
Data type: UNSIGNED_16
Index: 23340
d
= 5B2C
h
Waiting times for manual jog
Setting range
(min. value | unit | max. value)
0.000
s
65.000
Subcodes
Lenze setting
Info
C01235/1
5.000 s
Manual jog: Waiting time 2nd speed
• Time after which the first manual speed (
) is
accelerated to the second manual speed (
).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01236 | MCK: Speed follower
Data type: INTEGER_32
Index: 23339
d
= 5B2B
h
Speeds for position follower
Setting range
(min. value | unit | max. value)
-214748.3647
units/s
214748.3647
Subcodes
Lenze setting
Info
C01236/1
360.0000 units/s
PosFollower: Sync. speed
• Synchronisation speed for approaching the setpoint
position of the master.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01237 | MCK: Acceleration follower
Data type: INTEGER_32
Index: 23338
d
= 5B2A
h
Accelerations for position follower
Setting range
(min. value | unit | max. value)
-214748.3647
units/s2
214748.3647
Subcodes
Lenze setting
Info
C01237/1
720.0000 units/s2
Pos follower: Sync. accel.
• Acceleration for ramp-up to synchronisation speed.
C01237/2
720.0000 units/s2
Pos follower: Sync. decel.
• Deceleration for synchronisation speed ramp-down
to standstill (to the setpoint position of the master).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000