C01035 | l_curve_3: selectcurve, C01040 | l_srfg_1 linear ramp time, C01041 | l_srfg_1 s-ramp time – Lenze 8400 User Manual
Page 969: 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
969
16
Parameter reference
16.2
Parameter list | C01035
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01035
C01040
C01041
Parameter | Name:
C01035 | L_Curve_3: SelectCurve
Data type: UNSIGNED_16
Index: 23540
d
= 5BF4
h
From version 12.00.00
FB
: Selection of the tensile force profile
Selection list
Info
0 Linear tensile force profile
Use of L_Curve_3 for tensile force characteristic
1 Linear torque characteristic
2 Tensile force profile according to
characteristic
Subcodes
Lenze setting
Info
C01035/1
0: Linearer Zugkraftverlauf
: SelectCurve
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01040 | L_SRFG_1..2 linear ramp time
Data type: UNSIGNED_32
Index: 23535
d
= 5BEF
h
Symmetrical acceleration/deceleration time for the ramp function generator
Setting range
(min. value | unit | max. value)
0.001
s
999.999
Subcodes
Lenze setting
Info
C01040/1
100.000 s
: linear ramp time
C01040/2
100.000 s
: linear ramp time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01041 | L_SRFG_1..2 S-ramp time
Data type: UNSIGNED_32
Index: 23534
d
= 5BEE
h
S-ramp time for jerk-free acceleration
Setting range
(min. value | unit | max. value)
0.001
s
50.000
Subcodes
Lenze setting
Info
C01041/1
0.200 s
: S-ramp time
C01041/2
0.200 s
: S-ramp time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000