Ck16: time overflow manual control, Error m, Ck07: travel range limit exceeded – Lenze 8400 User Manual
Page 606: Ck05: error, following error 1, Ck06: error, following error 2, Will, Xx.0184.00153, Xx.0184.00154, Xx.0184.00155, Xx.0184.00015

9
Diagnostics & error management
9.10
Error messages of the operating system
606
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Ck14: Target position outside SW limit position [xx.0184.00015]
Ck16: Time overflow manual operation [xx.0184.00064]
Ck05: Following error 1 [xx.0184.00153]
Ck06: Following error 2 [xx.0184.00154]
Ck07: Travel range limit exceeded [xx.0184.00155]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: It has been attempted to position a target outside
the software limit positions (
).
• Select a target within the software limit positions.
• Increase permissible traversing range (change setting
of the software limit positions).
• Deactivate software limit position monitoring.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Manual PC control: The connection monitoring has
tripped.
• The online connection between the PC and the
controller has been interrupted for a longer period of
time than the timeout set in
• Check the communication link between the PC and
the controller.
• Check the voltage supply/function of the controller.
• Adjust the timeout (
).
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: Following error limit 1 (
) has been
exceeded.
• Optimise control mode.
• Increase following error limit.
• Deactivate following error monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: Following error limit 2 (
) has been
exceeded.
• Optimise control mode.
• Increase following error limit.
• Deactivate following error monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
MCK: The maximum travel distance has been exceeded.
• The maximum travel distance is displayed in
• Check profile parameters.
• Deactivate travel range limit monitoring.