C00823 | l_digitallogic_2: truth table, C00824 | l_digitallogic5_1: function, C00825 | l_digitallogic5_1: truth table – Lenze 8400 User Manual
Page 901: C00823, Is used, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
901
16
Parameter reference
16.2
Parameter list | C00823
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00823
C00824
C00825
Parameter | Name:
C00823 | L_DigitalLogic_2: Truth table
Data type: UNSIGNED_8
Index: 23752
d
= 5CC8
h
FB: Parameterisation of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00823/1
0: FALSE
: bIn3...bIn1=0 0 0
C00823/2
0: FALSE
: bIn3...bIn1=0 0 1
C00823/3
0: FALSE
: bIn3...bIn1=0 1 0
C00823/4
0: FALSE
: bIn3...bIn1=0 1 1
C00823/5
0: FALSE
: bIn3...bIn1=1 0 0
C00823/6
0: FALSE
: bIn3...bIn1=1 0 1
C00823/7
0: FALSE
: bIn3...bIn1=1 1 0
C00823/8
0: FALSE
: bIn3...bIn1=1 1 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00824 | L_DigitalLogic5_1: Function
Data type: UNSIGNED_8
Index: 23751
d
= 5CC7
h
FB
: Selection of the interna logic operation
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
1 bOut = 1
2 bOut = f (truth table)
The truth table parameterised in
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00825 | L_DigitalLogic5_1: Truth table
Data type: UNSIGNED_8
Index: 23750
d
= 5CC6
h
FB
: Parameter setting of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00825/1
0: FALSE
: bIn5...bIn1=0 0 0 0 0
C00825/2
0: FALSE
: bIn5...bIn1=0 0 0 0 1
C00825/3
0: FALSE
: bIn5...bIn1=0 0 0 1 0
C00825/4
0: FALSE
: bIn5...bIn1=0 0 0 1 1
C00825/5
0: FALSE
: bIn5...bIn1=0 0 1 0 0
C00825/6
0: FALSE
: bIn5...bIn1=0 0 1 0 1
C00825/7
0: FALSE
: bIn5...bIn1=0 0 1 1 0
C00825/8
0: FALSE
: bIn5...bIn1=0 0 1 1 1
C00825/9
0: FALSE
: bIn5...bIn1=0 1 0 0 0
C00825/10
0: FALSE
: bIn5...bIn1=0 1 0 0 1