C01074 | l_dfset_1: zero pulse divider, C01075 | l_dfset_1: synchronisation mode, C01076 | l_dfrfg_1: times – Lenze 8400 User Manual
Page 979: 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
979
16
Parameter reference
16.2
Parameter list | C01074
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01074
C01075
C01076
Parameter | Name:
C01074 | L_DFSET_1: Zero pulse divider
Data type: UNSIGNED_16
Index: 23501
d
= 5BCD
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
16384
Subcodes
Lenze setting
Info
C01074/1
0
: Divider for actual value zero pulse
C01074/2
0
: Divider for setpoint zero pulse
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01075 | L_DFSET_1: Synchronisation mode
Data type: UNSIGNED_8
Index: 23500
d
= 5BCC
h
From version 12.00.00
Selection list
0 Inactive
1 Permanent sync. without enable
(bZeroPulse)
2 Permanent sync. with enable
(bZeroPulse)
10 1x sync. - Angular diff. shortest path
setpoint
11 1x Sync. - Angular diff. Cw
12 1x Sync. - Angular diff. Ccw
13 1x Sync. - Angular diff. shortest path
act. value
Subcodes
Lenze setting
Info
C01075/1
0: Inactive
: Synchronisation mode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01076 | L_DFRFG_1: Times
Data type: UNSIGNED_32
Index: 23499
d
= 5BCB
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0.000
s
999.900
Subcodes
Lenze setting
Info
C01076/1
1.000 s
: Acceleration and deceleration time
C01076/2
0.000 s
: Deceleration time for quick stop
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000