C00570
C00572
C00574
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00570/1
0: No Reaction
Response if direct-axis current controller is limited
• e.g. at servo control (
C00570/2
0: No Reaction
Response if cross current controller is limited
• e.g. at servo control (
C00570/3
0: No Reaction
Response if torque setpoint is limited
• Limitation of the speed controller output, the
differential setpoint precontrol, and of the additive
torque at (
) servo control and (
) sensorless
vector control.
C00570/4
0: No Reaction
Response if field controller is limited
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00572 | Brake resistor overload threshold
Data type: UNSIGNED_8
Index: 24003
d
= 5DC3
h
Adjustable threshold for monitoring the brake resistor utilisation
• The response for reaching the threshold can be selected in
.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 100 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00574 | Resp. to brake resist. overtemp.
Data type: UNSIGNED_8
Index: 24001
d
= 5DC1
h
Response which is triggered if the threshold set in
for monitoring brake resistor utilisation is reached.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1