Motor control (MCTRL)
5.15
Internal interfaces | System block "LS_MotorInterface"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
nTorqueMotLimit_a
| INT
nTorqueGenLimit_a
| INT
Torque limitation in motor mode and in generator mode
• The drive cannot output a higher torque in motor/generator mode than set here.
• The applied values (any polarity) are internally interpreted as absolute values.
• If V/f characteristic control (VFCplus) is selected, limitation is indirectly
performed via a so-called I
max
controller.
• If sensorless vector control (SLVC) or servo control (SC) is selected, limitation has
a direct effect on the torque-producing current component.
• Scaling: 16384 ≡ 100 % M
max
Torque limits in motor and generator mode:
bTorqueInterpolatorOn
| BOOL
Torque setpoint interpolation
FALSE Deactivate interpolation
TRUE Activate interpolation
nVoltageAdd_a
| INT
Additive voltage impression
• An additional setpoint for the motor voltage can be specified via this process
input.
• If there are, for instance, different loads at the motor output end, it is possible to
apply a voltage boost at the starting time.
• If the value is negative, the voltage is reduced.
• Scaling: 16384 ≡ 1000 V
Stop!
Values selected too high may cause the motor to heat up due to the resulting
current!
bAutoBoostOn
| BOOL
AutoBoost function
• Motor voltage boost during the starting torque, controlled by process signals
from the function block interconnection.
FALSE Deactivate function
TRUE Activate function
nBoost_a
| INT
Additional setpoint for the motor voltage at speed = 0
• The entire voltage-frequency characteristic is provided with an offset.
• Scaling: 16384 ≡ 1000 V
Stop!
Values selected too high may cause the motor to heat up due to the resulting
current!
bPosCtrlOn
| BOOL
Position/angle control
FALSE Deactivate position/angle control.
TRUE Activate position/angle control.
Identifier
DIS code | data type
Information/possible settings
n
N
M
N
M
-M
N
-n
N
n
TorqueMotLim
TorqueGenLim
TorqueMotLim
TorqueMotLim
TorqueGenLim