C00323 | transmission mode can rx pdos, C00324 | can transmission blocking time, C00324/x – Lenze 8400 User Manual
Page 804: C00324/2, C00324/3, C00324/4, C00323/1, C00323/2, C00323/3, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C00323
804
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00323
C00324
Parameter | Name:
C00323 | Transmission mode CAN Rx PDOs
Data type: UNSIGNED_8
Index: 24252
d
= 5EBC
h
RPDO transmission type according to DS301 V4.02
• In the case of the RPDO serves as monitoring setting in the case of sync-controlled PDOs.
• The following transmission modes are supported:
• 0: Synchronous and acyclic
• 1 ... 240: Synchronous and cyclic
• 252: Synchronous - RTR only
• 253: Asynchronous - RTR only
• 254: Asynchronous - manufacturer-specific
• 255: Asynchronous - device-profile specific
• The basic setting for all PDOs is "Asynchronous - manufacturer-specific" (254).
• Illustration of the CANopen objects
...
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C00323/1
254
Transmission mode CAN1 IN
C00323/2
254
Transmission mode CAN2 IN
C00323/3
254
Transmission mode CAN3 IN
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00324 | CAN transmission blocking time
Data type: UNSIGNED_16
Index: 24251
d
= 5EBB
h
From version 06.00.00
Blocking time for the transmission of the emergency telegram and the process data
Note:
If the "Asynchronous - manufacturer-specific/device profile-specific" transmisson type is set, the transmission cycle
timer is reset to 0 if event-controlled transmission has been triggered.
Example: Cycle time (
) = 500 ms, blocking time = 100 ms, data change sporadically:
• In the case of a sporadic data change < 500 ms, due to the blocking time set, transmission takes place every
100 ms (event-controlled transmission) as quickly as possible.
• In the case of a sporadic data change > 500 ms, due to the cycle time set, transmission takes place every 500 ms
(cyclic transmission).
Setting range
(min. value | unit | max. value)
0
ms
6500
Subcodes
Lenze setting
Info
C00324/1
0 ms
CAN emergency blocking time
C00324/2
0 ms
CAN1_OUT blocking time
C00324/3
0 ms
CAN2_OUT blocking time
C00324/4
0 ms
CAN3_OUT blocking time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1