9 stop, 1 parameter setting, 2 requesting the operating mode – Lenze 8400 User Manual
Page 528: Stop, Parameter setting, Requesting the operating mode, 8basic drive functions (mck)

8
Basic drive functions (MCK)
8.9
Stop
528
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.9
Stop
If the "normal stop" operating mode is active, the drive is brought to a standstill with a
parameterisable deceleration ramp.
8.9.1
Parameter setting
Short overview of parameters for "Normal stop" operating mode:
8.9.2
Requesting the operating mode
Request for "Normal stop" operating mode by means of the
:
If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode
FB, the wOperationMode and bOperationMode_1...8 process
inputs are available.
Parameter
Info
Lenze setting
Value Unit
Normal stop: Deceleration
720.0000 units/s2
Stop: S-ramp time
0.000 s
MCK control word
Bit 31
...
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
OpMode_Bit3
OpMode_Bit2
OpMode_Bit1
OpMode_Bit0
X
...
X
0
1
0
0
X = Status not significant