beautypg.com

C00024 | ls_driveinterface: bnactcompare, C00026 | ainx: offset, C00027 | ainx: gain – Lenze 8400 User Manual

Page 750: C00028 | ainx: input voltage, C00024, C00028/1, C00026/1, C00027/1, 16 parameter reference

background image

16

Parameter reference

16.2

Parameter list | C00024

750

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00024

C00026

C00027

C00028

Parameter | Name:

C00024 | LS_DriveInterface: bNActCompare

Data type: INTEGER_16

Index: 24551

d

= 5FE7

h

Threshold for the actual speed comparison

• This parameter serves to set a threshold that is compared with the actual speed value.

• If the value falls below this threshold, the bNactCompare output sets the

LS_DriveInterface

system block to

TRUE.

• Switching hysteresis = +1 %

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00026 | AINx: Offset

Data type: INTEGER_16

Index: 24549

d

= 5FE5

h

Offset for analog input

Analog terminals

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00026/1

0.00 %

AIN1: Offset

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00027 | AINx: Gain

Data type: INTEGER_32

Index: 24548

d

= 5FE4

h

Gain for analog input

Analog terminals

Setting range

(min. value | unit | max. value)

-100.0000

100.0000

Subcodes

Lenze setting

Info

C00027/1

1.0000

AIN1: Gain

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C00028 | AINx: Input voltage

Data type: INTEGER_16

Index: 24547

d

= 5FE3

h

Display of the input voltage at the analog input

Analog terminals

Display range

(min. value | unit | max. value)

-10.00

V

10.00

Subcodes

Info

C00028/1

AIN1: Input voltage

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100