_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00711/5
0: Not connected
: bJogSpeed1
Control input for fixed speed selection value 1
C00711/6
0: Not connected
: bJogSpeed2
Control input for fixed speed selection value 2
C00711/7
0: Not connected
: bMPotEnable
Control input for activation of motor potentiometer
C00711/8
0: Not connected
: bMPotUp
Control input for motor potentiometer ramp-up
C00711/9
0: Not connected
: bMPotDown
Control input for motor potentiometer ramp-down
C00711/10
0: Not connected
: bMBrakeRelease
Control input for manual holding brake release request
C00711/11
0: Not connected
: bPosCtrlOn
Control input for activation of position controller
C00711/12
0: Not connected
: bLimitSwitchPos
Input for positive hardware limit switch signal
C00711/13
0: Not connected
: bLimitSwitchNeg
Input for negative hardware limit switch signal
C00711/14
0: Not connected
: bReleaseLimitSwitch
Control input for hardware limit switch retracting
request
C00711/15
0: Not connected
: bManJogPos
Control input for manual jog in positive direction request
C00711/16
0: Not connected
: bManJogNeg
Control input for manual jog in negative direction
request
C00711/17
0: Not connected
: bManEnable2ndSpeed
Control input for activation of the second manual speed
for manual jog
C00711/18
0: Not connected
: bEnableSpeedOverride
Control input for activation of speed override
C00711/19
0: Not connected
: bEnableAccOverride
Control input for activation of acceleration override
C00711/20
0: Not connected
: bHomeStartStop
Control input for start/stop homing
C00711/21
0: Not connected
: bHomeSetPosition
Control input for setting the home position
C00711/22
0: Not connected
: bHomeResetPosition
Control input for reset of "Home position known"
C00711/23
0: Not connected
: bHomeMark
Input for pre-stop signal for homing
C00711/24
0: Not connected
: bPosSetProfilePosition
Control input for accepting the profile position in the
profile data set
C00711/25
0: Not connected
: bPosSetActualPosition
Control input for accepting the current position in the
profile data set
C00711/26
0: Not connected
: bPosExecute
Control input for positioning start
C00711/27
0: Not connected
: bPosFinishTarget
Control input for completion of positioning to target
position
Parameter | Name:
C00711 | LA_TabPos: Digital connection list
Data type: UNSIGNED_16
Index: 23864
d
= 5D38
h