C01056 | l_processctrl_1: controller gain, C01057 | l_calcdiameter_1: current diameter, C01058 | l_posctrllin 1-2: limit stop – Lenze 8400 User Manual
Page 973: 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
973
16
Parameter reference
16.2
Parameter list | C01055
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01055
C01056
C01057
C01058
Parameter | Name:
C01055 | L_ProcessCtrl_1: Correcting variable limitation
Data type: UNSIGNED_8
Index: 23520
d
= 5BE0
h
From version 12.00.00
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C01055/1
0: FALSE
: Correcting variable limitation
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01056 | L_ProcessCtrl_1: Controller gain
Data type: UNSIGNED_16
Index: 23519
d
= 5BDF
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0.00
100.00
Subcodes
Lenze setting
Info
C01056/1
0.10
: Controller gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01057 | L_CalcDiameter_1: Current diameter
Data type: UNSIGNED_32
Index: 23518
d
= 5BDE
h
From version 12.00.00
Display range
(min. value | unit | max. value)
0.000
mm
10000.000
Subcodes
Info
C01057/1
: Current diameter
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01058 | L_PosCtrlLin 1-2: Limit stop
Data type: UNSIGNED_8
Index: 23517
d
= 5BDD
h
From version 12.00.00
Selection list
0 deactivated
1 activated
Subcodes
Lenze setting
Info
C01058/1
0: Deactivated
: Limit stop
C01058/2
0: Deactivated
: Limit stop
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1