C00077 | sc: vp field controller, C00078 | sc: tn field controller, C00079 | sc: settings – Lenze 8400 User Manual
Page 758: C00077, C00078, Controller feedforward control, C00079/1, C00079/4, Tive, Of the fie

16
Parameter reference
16.2
Parameter list | C00077
758
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00077
C00078
C00079
Parameter | Name:
C00077 | SC: Vp field controller
Data type: UNSIGNED_16
Index: 24498
d
= 5FB2
h
Gain factor Vp of the field controller for servo control (
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
500.00 12.80
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00078 | SC: Tn field controller
Data type: UNSIGNED_16
Index: 24497
d
= 5FB1
h
Reset time Tn of the field controller for servo control (
)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
6000.0 256.0 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00079 | SC: Settings
Data type: UNSIGNED_8
Index: 24496
d
= 5FB0
h
Configuration of different options for servo control (
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00079/1
0: Off
: Current controller - feedforward control
• Feedforward control/decoupling network of the
current controller.
C00079/2
1: On
: Adapt. field weakening controller
• Speed-dependent adaptive field weakening
controller.
C00079/3
0: Off
: n-ctrl anti-wind-up
• "Anti-wind-up" effect of the speed controller in case
of an output voltage limitation in the field weakening
range.
C00079/4
1: On
Field weakening for synchronous motors
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1