18 function library – Lenze 8400 User Manual
Page 1250

18
Function library
18.1
Function blocks | L_Curve_3
1250
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Linear torque characteristic
• nD0_a serves to define at which diameter the tensile force decrease is to start.
• Since in this characteristic selection, the linear torque profile is in the focus, define in this case
the slope of the torque curve via dnCurveCtrl_n:
• When nCurveCtrl_a = 100 %, the tensile force remains unchanged.
• When nCurveCtrl_a = 0 %, the tensile force is reduced up to D0/DMax.
Characteristic for a linear torque profile (
= 2)
Characteristic
Tensile force
Diameter
Function for D > D0:
D Current diameter (nDiameter_a)
D0 Initial point for diameter dependency (nD0_a)
HW Tensile force valuation (nCurveCtrl_a)
Example: Steepness of the torque curve
Characteristic
Torque
Diameter
D Current diameter (nDiameter_a)
D0 Initial point for diameter dependency (nD0_a)
DMin
(DMax)
D0
100 %
100 %
0 %
100 %
nCurveCtrl_a = 0 %
HW
HW
100 % HW
–
(
) D0
⋅
D
------------------------------------------------
+
DMin
(DMax)
D0
100 %
100 %
0 %
100 %
nCurveCtrl_a
0 %
50 %