C01201 | mck: cycle, C01202 | mck: im motor/process, C01203 | mck: ig motor/position encoder – Lenze 8400 User Manual
Page 994: C01202/1, C01202/2, C01203/1, C01203/2, C01201/1, Hen the cycle, C1201/1

16
Parameter reference
16.2
Parameter list | C01201
994
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01201
C01202
C01203
Parameter | Name:
C01201 | MCK: Cycle
Data type: INTEGER_32
Index: 23374
d
= 5B4E
h
From version 06.00.00
Cycle for Modulo measuring system
• When the cycle is set to 0 units (Lenze setting), the traversing range is unlimited (classical measuring system).
Activation of the Modulo measuring system
Setting range
(min. value | unit | max. value)
0.0000
units
214748.3647
Subcodes
Lenze setting
Info
C01201/1
0.0000 units
MCK: Cycle
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01202 | MCK: iM motor/process
Data type: UNSIGNED_16
Index: 23373
d
= 5B4D
h
Gearbox factor - motor
• Entry of the gearbox factor as numerator/denominator ratio (numerator = motor speed and denominator =
output speed of gearbox) or from the number of teeth of the gearbox arrangement.
Setting range
(min. value | unit | max. value)
1
65535
Subcodes
Lenze setting
Info
C01202/1
1
MCK: iM: Numerator gearbox factor Z2
C01202/2
1
MCK: iM: Denominator gearbox factor Z1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01203 | MCK: iG motor/position encoder
Data type: UNSIGNED_16
Index: 23372
d
= 5B4C
h
Gearbox factor - position encoder
• Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator
= position encoder speed.
Setting range
(min. value | unit | max. value)
1
65535
Subcodes
Lenze setting
Info
C01203/1
1
MCK: iG: Numerator (motor speed)
C01203/2
1
MCK: iG: Denominator (encoder speed)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1