C00073 | imax/m controller gain, C00074 | reset time imax/m controller, C00075 | vp current controller – Lenze 8400 User Manual
Page 757: C00076 | ti current controller, C00075, C00076, C00073/1, C00074/1, C00074, C00073

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
757
16
Parameter reference
16.2
Parameter list | C00073
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00073
C00074
C00075
C00076
Parameter | Name:
C00073 | Imax/M controller gain
Data type: UNSIGNED_16
Index: 24502
d
= 5FB6
h
Amplification factor Vp of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0.00
100.00
Subcodes
Lenze setting
Info
C00073/1
0.25
: Vp Imax controller
• After the motor to be used has been selected from the
motor catalogue, the suitable value can be entered
automatically.
C00073/2
1.25
: Vp torque controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00074 | Reset time Imax/M controller
Data type: UNSIGNED_16
Index: 24501
d
= 5FB5
h
Reset time Ti of certain controllers for different motor control modes
Setting range
(min. value | unit | max. value)
0
ms
9990
Subcodes
Lenze setting
Info
C00074/1
65 ms
: Ti Imax controller
C00074/2
30 ms
: Ti torque controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00075 | Vp current controller
Data type: UNSIGNED_16
Index: 24500
d
= 5FB4
h
Gain factor Vp of the current controller for servo control (
) and certain inverter functions (parameter
identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
V/A
500.00 7.00 V/A
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00076 | Ti current controller
Data type: UNSIGNED_16
Index: 24499
d
= 5FB3
h
Reset time Ti of the current controller for servo control (
) and certain inverter functions (parameter identification,
flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
500.00 10.61 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100