10 pc manual control, 1 activating pc manual control, Activating pc manual control – Lenze 8400 User Manual
Page 86: 3commissioning

3
Commissioning
3.10
PC manual control
86
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10
PC manual control
This function extension is available from version 06.00.00 onwards and is supported by the
»Engineer« from version 2.13 onwards!
For test and demonstration purposes, PC manual control can be used to manually control various
drive functions via the »Engineer« when an online connection has been established.
Supported drive functions:
• Speed control (follow a speed setpoint)
• Activate/deactivate quick stop
• Set/reset home position
• Manual jog
• Positioning (relative or absolute)
More control functions:
• Reset error message
•
Set digital/analog outputs (in preparation)
Diagnostic functions:
• Display of the actual speed value and motor current (in a temporal characteristic)
• Display of the current device status
• Display of the status determining error
•
Display of the status of the digital/analog inputs (in preparation)
3.10.1
Activating PC manual control
Stop!
PC manual control must be explicitly activated by the user.
If PC manual control is activated, the controller is inhibited via device command
(
) first.