2 led status displays, Led status displays, Status displays – Lenze 8400 User Manual
Page 554: 9diagnostics & error management

9
Diagnostics & error management
9.2
LED status displays
554
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.2
LED status displays
Information on some operating statuses can quickly be obtained via LED displays:
[9-1]
LED display on the controller front panel
',
',
','2
','2
',
',
5'<
(55
9
6
%UDNH
%865'<
%86(55
/LQN
/LQN
66WDWH
6(UURU
6$FNQZ
6(QDEOH
'5
9
6WDWXV
&RP
6DIHW\
,2
,2
Labelling
Colour
Status
Description
DRV-RDY
green
On
Standard device ready for
operation
DRV-ERR
red
On
Warning/trouble/fault
24V-S
green
On
24-V voltage available
Brake
yellow
Off
Motor holding brake not triggered (applied)
On
Motor holding brake triggered (released)
LED status displays for communication
BUS-RDY
green
Off
Communication not initialised
Blinking
Communication has been established
On
Communication has stopped
BUS-ERR
red
Blinking
With PROFINET: Node detection
Fast blinking With PROFINET: Nodes not detected
On
Communication error
Link-1
Link-2
yellow
Off
Communication is not active
Blinking
Initialisation
Fast blinking With PROFINET:
Communication is active, telegrams are sent.
LED status displays for integrated safety
Note: The status of the safety option 10 is exclusively signalled via the "S-Enable" display.
S-State
green
Off
Communication between Standard device and safety
engineering is not possible
Blinking
Integrated safety is in service state
On
Communication between standard device and safety system
has been established
S-Error
red
Off
Error-free operation
Blinking
Integrated safety system is not supported by the standard
device
On
Warning/trouble/fault
S-Acknw
yellow
On
Acknowledgement of a parameter set acceptance is required
S-Enable
yellow
Blinking
Safety function system active (unsafe display)
On
Controller enabled