6 ramp function generator for the main setpoint, 6 ramp function generator for the main setpoint 9, 18 function library – Lenze 8400 User Manual
Page 1339
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1339
18
Function library
18.1
Function blocks | L_NSet_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.117.6 Ramp function generator for the main setpoint
The setpoint is now led via a ramp function generator with linear characteristic. The ramp function
generator converts setpoint step-changes at the input into a ramp.
[18-47] Acceleration and deceleration times
• t
ir
and t
if
are the desired times for changing between w1 and w2.
• S-ramps are possible by selecting S-ramp times.
• The t
ir
/t
if
values are converted into the required Ti times according to the following formula:
Setting and selection of Ti times
Via parameters, you can select 16 different Tir and Tif times each for the ramp function generator.
• The selection is made via the binary coded selection inputs bTI1 ... bTI8:
w1, w2 = change of the main setpoint as a function of t
ir
and t
if
RFG-OUT = output of the ramp function generator
RFG-OUT
100 %
w2
w1
t
0 %
t
ir
t
ir
T
ir
T
ir
Selection inputs
Used
Acceleration time
Used
Deceleration
time
bTI8
bTI4
bTI2
bTI1
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
T
ir
t
ir
100 %
w2 w1
–
-----------------------
⋅
=
T
if
t
if
100 %
w2 w1
–
-----------------------
⋅
=