C00916 | motor cable cross-section, C00917 | motor cable resistance, C00918 | sc: start motor magnetising current – Lenze 8400 User Manual
Page 951: C00919 | moment of inertia from load, C00919/1, C00916, Motor c, C00917, Set th, Whic
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
951
16
Parameter reference
16.2
Parameter list | C00916
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00916
C00917
C00918
C00919
C00922
Parameter | Name:
C00916 | Motor cable cross-section
Data type: UNSIGNED_16
Index: 23659
d
= 5C6B
h
Motor cable cross-section of a phase/cable for calculating the motor cable resistance
• The calculated motor cable resistance is displayed in
Setting range
(min. value | unit | max. value)
Lenze setting
0.50
mm^2
100.00 6.00 mm^2
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00917 | Motor cable resistance
Data type: UNSIGNED_16
Index: 23658
d
= 5C6A
h
Display of the motor cable resistance of a motor cable phase
• The motor cable resistance is calculated from the motor cable length set in
and the motor cable cross-
Display range
(min. value | unit | max. value)
0
mOhm
64000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00918 | SC: Start motor magnetising current
Data type: UNSIGNED_8
Index: 23657
d
= 5C69
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
90 87 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00919 | Moment of inertia from load
Data type: UNSIGNED_32
Index: 23656
d
= 5C68
h
From version 12.00.00
In order to take account of mass inertias changing during the process (e.g. reels) when optimising the response to
setpoint changes, the maximum value of the changing moment of inertia must be set here. The process signal
nInertiaAdapt_a of the
SB can then be used in the process to dynamically control what
percentage of it is to be taken into account for the setpoint feedforward control.
Setting range
(min. value | unit | max. value)
0.00
kg cm^2
6000000.00
Subcodes
Lenze setting
Info
C00919/1
0.00 kg cm^2
Load moment of inertia
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00922 | ICM_DiagnosticCounter
Data type: UNSIGNED_16
Index: 23653
d
= 5C65
h
This code is for device-internal use only and must not be written to by the user!