Device control (DCTRL)
4.1
Device commands (C00002/x)
104
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.5
Activate/deactivate quick stop
The
= "1: On / start" device command activates the quick stop function, i.e. the motor
control is separated from the setpoint selection, and within the deceleration time parameterised
the motor is brought to a standstill (n
act
= 0).
•
From version 12.00.00
,
can be used to activate the position control during ramp-
down and/or at standstill if the following is provided:
• A position feedback system is set in
.
• The position control is activated (input bPosCtrlOn at the
system
block is set to TRUE, see the following configuration cutout).
• The inputs nPosCtrlOutLimit_a and nPosCtrlPAdapt_a at the
are set to 100 %.
[4-1]
Activate required configuration for the "Position control during ramp-down and/or at standstill" function
• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit is set if the auto-DCB function has been activated via
.
The
= "0: Off / ready" device command deactivates the quick stop again, provided that
no other source of a quick stop is active.
Parameter
Info
Lenze setting
Value Unit
Decel. time - quick stop
2.000 s
Parameter
Info
Lenze setting
Bit 0: Standstill position-controlled
0
Bit 1: Ramp position-controlled
0
E3RV&WUO2Q
E3RV&WUO2Q
/6B0RWLRQ&RQWURO.HUQHO
E3RV&WUO2QB
"
/6B0RWRU,QWHUIDFH
"
0RWRU
LQWHUIDFH
0&.
Q3RV&WUO3$GDSWBD
Q3RV&WUO2XW/LPLWBD
758(