C02607 | holding brake: status, C02607, 16 parameter reference – Lenze 8400 User Manual
Page 1056

16
Parameter reference
16.2
Parameter list | C02607
1056
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02607
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Brake applied
Holding brake is completely applied
Bit 1 Brake released
Holding brake is completely released
Bit 2 Feedforward control active
Feedforward control for holding of the load via the motor
is active before the holding brake releases.
Bit 3 Closing active
The brake closing time (
) expires
Bit 4 Forced release active
In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bMBrakeRelease = TRUE
Bit 5 Release active
The brake release time (
Bit 6 Setpoint synchronisation active
A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Signalling contact error
The status monitoring has tripped.
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT