C00995 | slpsm: controlled current setpoint, C00996 | slpsm: switching speed, C00997 | slpsm: filter cutoff frequency – Lenze 8400 User Manual
Page 963: C00998 | slpsm: filter time rotor position, C00998/1, C00998/2, C00995/1, C00995/2, C00996/1, C00996/2

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
963
16
Parameter reference
16.2
Parameter list | C00995
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00995
C00996
C00997
C00998
Parameter | Name:
C00995 | SLPSM: Controlled current setpoint
Data type: UNSIGNED_16
Index: 23580
d
= 5C1C
h
From version 12.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
5.00
%
400.00
Subcodes
Lenze setting
Info
C00995/1
100.00 %
SLPSM: Controlled accelerating current
C00995/2
20.00 %
SLPSM: Controlled standstill current
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00996 | SLPSM: Switching speed
Data type: INTEGER_16
Index: 23579
d
= 5C1B
h
From version 12.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C00996/1
13.00 %
SLPSM: Switching speed, closed-loop control
C00996/2
8.00 %
SLPSM: Switching speed, open-loop control
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00997 | SLPSM: Filter cutoff frequency
Data type: INTEGER_16
Index: 23578
d
= 5C1A
h
From version 12.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 5.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
Data type: INTEGER_16
Index: 23577
d
= 5C19
h
From version 12.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
0.5
ms
20.0
Subcodes
Lenze setting
Info
C00998/1
3.0 ms
SLPSM: Filter time rotor position
C00998/2
5.0 ms
SLPSM: Filter time actual speed value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10