beautypg.com

1 assign control functions to the remote control, Assign control functions to the remote control 9, 18 function library – Lenze 8400 User Manual

Page 1439

background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1439

18

Function library

18.2

System blocks | LS_IRInterface

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.2.12.1 Assign control functions to the remote control

The control functions are assigned to the keys of the remote control via interconnection in the FB

Editor. The following example shows two principal options.

Option 1: Assignment of function/key in the controller
For this purpose, the SB LS_IRInterface is directly connected to the control inputs of the application

block:

[18-74] Principle: Direct assignment of keys to control inputs of the application

• Advantage: Independent of the higher-level control, some functions can be exclusively

executed via remote control (e.g. emergency operation in case the higher-level control fails).

• Disadvantage: It is not possible to influence the control signals of the higher-level control by

means of the remote control.

/3B0FL,Q

/3B&DQ,Q

/3B0FL2XW

/3B&DQ2XW

/$B

/6B,5,QWHUIDFH

21

2))

)

)

)

)