C00560 | fan switching status, C00561 | failure indication, C00565 | resp. to mains phase failure – Lenze 8400 User Manual
Page 846: C00565, E logbook and, C00561/3, Stil, Motor phas, C00561/4, C00561/5

16
Parameter reference
16.2
Parameter list | C00560
846
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00560
C00561
C00565
Parameter | Name:
C00560 | Fan switching status
Data type: UNSIGNED_8
Index: 24015
d
= 5DCF
h
Display of the function status of the device fans
Selection list
0 Off
1 On
2 No fan
Subcodes
Info
C00560/1
Switching status - internal fan WU
C00560/2
Switching status - internal fan DU
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00561 | Failure indication
Data type: UNSIGNED_8
Index: 24014
d
= 5DCE
h
Error status display of device fan
Selection list
0 No error
1 Fault
Subcodes
Info
C00561/1
Internal fan WU
C00561/2
Internal fan DU
C00561/3
Motor phase U
•
From version 12.00.00
C00561/4
Motor phase V
•
From version 12.00.00
C00561/5
Motor phase W
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00565 | Resp. to mains phase failure
Data type: UNSIGNED_8
Index: 24010
d
= 5DCA
h
Response to the failure of mains phases
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1