C00999 | slpsm: pll gain, C01000 | mctrl: status, C01000 – Lenze 8400 User Manual
Page 964: Displays the set mot, C00999, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C00999
964
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00999
C01000
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 12.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
1000 400 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
From version 12.00.00
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 SLPSM: Speed closed-loop control
Bit 1 SLPSM: Speed open-loop control
Bit 2 Motor ASM
Bit 3 Motor PSM
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved